ASTM E547 PDF

based on specific design pressures (DP). ▫ Water penetration resistance (ASTM E and ASTM E). ▫ Uniform load deflection test (ASTM. ASTM International E Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Wall by Cyclic Static Air Pressure. ASTM E Standard test method for water penetration of exterior windows, skylights, doors, and curtain walls by cyclic static air pressure difference.

Author: Fenrihn Yozuru
Country: Philippines
Language: English (Spanish)
Genre: Art
Published (Last): 25 June 2014
Pages: 22
PDF File Size: 12.93 Mb
ePub File Size: 6.81 Mb
ISBN: 346-6-37220-495-8
Downloads: 6662
Price: Free* [*Free Regsitration Required]
Uploader: Meshicage

However, unlike E the E test attempts to simulate more real life exposure by cycling the pressure across the test specimen as the test procedure progresses.

Sstm service, the performance will also depend on the rigidity of supporting construction and on the resistance of components to deterioration by various causes, vibration, thermal expansion and contraction, etc. In applying the results of tests by this test method, note that the performance of a wall or its components, or both, may be a function of proper installation and adjustment. Some designs are more sensitive than others to this upward moving water.

Failures during quality assurance new construction testing can result in unnecessary delays that impact your bottom line. For specific hazard statements, see 7. Water that penetrates the assembly, but does not result in a failure as defined herein, may have adverse effects xstm the performance of contained materials such as sealants and insulating or laminated glass.

MISSION Professional services based on accurate information that helps you or w547 company make the right decision regarding your project or asset. BDG utilizes professional testing equipment that is calibrated to each specific testing standard for accurate results.

ASTM E 547-16

If you are looking for a reputable second or third-party testing company to perform accurate professional testing, provide concise reports, and help you through the entire process, contact BDG today. We provide testing services throughout the United States from our headquarters located in Atlanta, GA. In service, the asstm will also depend on the rigidity of supporting construction and on the resistance of components to deterioration by various causes, vibration, thermal expansion and contraction, etc.

Blog Building Wall Assemblies: In recent earlier blogs I reviewed the primary wall types and how asmt created different challenges for adhesives and sealants in preventing water ingress into the wall assembly. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard. The ASTM E Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference is a testing standard of procedures used to determine the water penetration resistance of windows, curtain walls, skylights, and doors when water is applied using a calibrated spray apparatus while simultaneously applying cyclic static pressure to opposite sides of the test specimen.

  ELRO M12 BEDIENUNGSANLEITUNG PDF

These factors should be fully considered prior to specifying the test pressure difference to be used.

The E test, like E, provides the details of the instrumentation similar to ASTM E to create a pressure difference across a multitude of building assemblies during the calibrated water spray minimum rate of 3. See the summary for E in this link: It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

The air-pressure differences acting across a building envelope vary greatly. Satm no case aetm there be less than two test cycles, and no cycle shall be less than 5 minutes in duration.

Water that penetrates the assembly, but does not result in a failure as defined herein, may have adverse effects on the performance of contained materials such as sealants and insulating or laminated glass. These factors should be fully considered prior to specifying the test pressure difference to be used.

In my last blog I listed the steps for the E test and in this blog I have left kept those steps but in bold font for comparison. Give us a call today for more information or to discuss you next project.

Norma ASTM E()

In applying the results of tests by this aatm method, note that the performance of a wall or its components, or both, may be a function of proper installation and adjustment.

This test method does not address these issues.

Link to Active This link will always route to the current Active version of the standard. The test-pressure difference or differences at which atm penetration is to be determined, unless otherwise specified, shall be Pa 2. To watch asrm three minute video for an Asym For a negative pressure system, the water-spray grid would be located outside the chamber and the air supply would be replaced by an air-exhaust system.

BDG has extensive knowledge of most building systems and specializes in forensic water intrusion investigations. Historical Version s – view previous versions of standard. Professional services based on accurate information that helps you or your company make the right decision regarding your project or asset. Some designs are more sensitive than others to this upward moving water.

  JAIPUR BRTS PDF

ASTM E 547

atsm Most generic specifications call for a minimum testing pressure of 6. The testing pressure differential is usually determined by the testing specifier.

The air-pressure differences acting across a building envelope vary greatly. This test method does not address these issues. This test method does not identify unobservable liquid water which may penetrate into the test specimen. This test method does not identify unobservable liquid water which may penetrate into the test specimen. Our field consultants are properly trained and knowledgeable of all testing standards.

It is difficult to simulate the identical complex wetting conditions that can be encountered in service, with large wind-blown water drops, increasing water drop impact pressures with increasing wind velocity, and lateral or upward moving air and water.

It is difficult to simulate the identical complex wetting conditions that can be encountered in service, with large wind-blown water drops, increasing water drop impact pressures with increasing wind velocity, and lateral or upward moving air and water. The water spray system has nozzles spaced on e5547 grid to deliver water so that the test specimen is wet uniformly, including those areas vulnerable to water penetration. For specific hazard statements, see 7. The most essential steps in running the E test, once the wall assembly is attached and sealed to the ASTM E test wall, are listed below.

This allows us to not only properly test fenestrations on new construction projects, but also pinpoint the cause of any test failures and provide accurate recommendations to achieve successful testing results. In my last blog, I focused on a long standing and very useful laboratory test used to measure water penetration: The values given in parentheses are mathematical conversions satm inch-pound units that are provided for information only and are not considered standard.

The ASTM E testing is performed by applying water to the exterior of the test specimen while lowering the pressure inside by means of an air chamber built on the inside or opposite side of the test specimen. Building Diagnostics Group, Inc. The list below shows what we have discussed so far and the next steps. It is the responsibility of the user of this standard to establish appropriate safety and health practices and satm the applicability of regulatory limitations prior to use.

See the illustration below.